Three different soil test meters in one device; Measures moisture, pH/Acidity, and light. 100% Accuracy; Easy to read moisture, pH and light levels; Perfect monitor for growing healthy plants. Takes the guesswork out of gardening; Know exactly when to water, amend your soil or adjust lighting. Compact, portable & easy to use, just plug and use; Compact soil meter works…
4 Different Reading on one Screen On-Screen Battery Level Indicator Unit change Switch 200 mm probe to measure the root level Yellow Backlight Screen Power sleep mode for long battery life Portable and Plug and Play device
Low current consumption (typical 30 mA) CW or pulse operation Flat profile Long detection range (20 m) Supply voltage: 4.75V to 5.25V X-Band Frequency: 10.525 GHz Minimum Power Output: 13 dBm EIRP
Transmission signal processing control chip RCWL-9196 Wide operating voltage range 4.0V to 28.0V Penetrating detection capability, compared with the traditional infrared feeling PIR Adjustable Block time and distance Operating Current: 2.8mA (typical); 3mA (max) Detection Distance: 5-9m Transmitting Power: 20mW (typical); 30mW (max)
LC 5A Over-current protection Sensor module uses a current transformer to collect the AC signal to achieve the relay over-current signal output within 0-5A. Relay pull while over-current, relay released while not over-current
Onboard precision microcurrent transformer. Onboard sampling resistor. The module can measure AC currents less than 5A, the corresponding analog output 5A/5mA. Rated input current: 5A Rated output current: 5mA Change: 1000: 1 The linear range: 0 ~ 10A (100 ohms) Linearity: 0.2%
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 30A Sensitivity: 100mV/A
Low-noise analog signal path Device bandwidth is set via the new FILTER pin 5 µs output rise time in response to step input current Small footprint, low-profile SOIC8 package 2.1 kVRMS minimum isolation voltage from pins 1-4 to pins 5-8 Supply Voltage: 4.5V~5.5V DC Measure Current Range: 20A Sensitivity: 100mV/A
Low-noise analog signal path. Device bandwidth is set via the new FILTER pin. 5 µs output rise time in response to step input current. Small footprint, low-profile SOIC8 package. 2.1 kV RMS minimum isolation voltage from pins 1-4 to pins 5-8.
Operating voltage (VCC): 3 V to 5V Operating current: 120μA (typical) 190μA (max) Operating Temperature: -40°C ~ +85°C Photodiode sensitive to UV-A and UV-B Embedded operational amplifier Analog voltage output Low supply current (300uA type) and low standby current (0.1uA type)
"🎉 Enjoy exclusive discounts! Use coupon codes at checkout & get FREE delivery on eligible orders. Shop now! 🚚✨" Dismiss